Choose your region and language

Go

Menu

RTU500 series modules

Flexible extension modules for RTU500 series

The RTU500 series modules can be used with all product lines to provide additional and extended functionality. The modules provide special functions to complete a RTU for a specific application.

Multimeters

RTU’s multimeter devices enable direct measurement of voltage, current and power. The configuration of the devices is completely integrated into the easy-to-use RTUtil500 and the DIN rail wizard. Multimeters provide for a detailed monitoring of the network. To locate a fault, multimeters offer fault current detection with directional information. Additionally, the increased and reliable information about the network protect your investments and allow for precise new investments, if need be.

Communication

Flexibility of communication is a precondition for modern RTU systems. To guarantee an error-free and comprehensive communication to a variety of devices, the RTU500 series offers modules for Ethernet and serial communication.

Our offering

560PSU40 DIN rail power supply unit for 110...220 V DC, 230 V AC

Power supply module for DIN rail mounting

  • Input voltage: 85...264 V AC or 85...375 V DC
  • Output voltage: 24-28 V DC, max. 2.5 A, 60 W
  • Suitable for supply of up to 8 interposing modules 23BEx0/23BA40/560FSMxx/560MPR01/560CVDxx/RTU540/RTU511
  • Suitable for redundant supply

560PSU41 DIN rail power supply unit for 24...60 V DC

Power supply module for DIN rail mounting

  • Output voltage: 24 V DC, max. 2.5 A, 60 W
  • Suitable for supply of up to 8 interposing modules 23BEx0/23BA40/560FSMxx/560MPR01

23VG23 Mains adapter 115...230 V AC, 48 W

Mains adapter AC/DC converter for 230 or 115 V AC input, output 24 V DC, 2 A max.

  • Designed for use with back-up battery 24 V DC nominal for maximum 1.5 hours full operation

23VG24 Mains adapter 115...230 V AC, 240 W

Mains adapter AC/DC converter for 230 or 115 V AC input, output 24 V DC, 10 A max.

560CVD03 Multimeter, 1A/5A, 3U3I

  • CT/VT interface with 3 voltage and 3 current inputs for direct monitoring of 3 wire 85…400 V AC
  • 1 A/ 5 A inputs from AC transformers
  • Serial interface to RTU500 (RS-485)

560CVD11 Multimeter with FCD, 4U/4I

It can be set to automatically change the screen of measurement page and each screen display every 6 seconds.

  • CT/VT interface with 3 voltage and 3 current inputs for direct monitoring of 3 wire 85…400 V AC
  • 1 A/ 5 A inputs from AC transformers
  • Serial interface to RTU500 (RS-485)
  • With display on front

560CVD11 Multimeter with FCD, 4U/4I

  • CT/VT interface with 4 voltage and 4 current inputs for direct monitoring of 3/4 wire 10…300 V AC
  • 1 A/ 5 A signals
  • Serial interface to RTU560 (RS-485)

500CVD21 Multimeter with FCD, 4U/24I

  • CT/VT interface with inputs for direct monitoring of 3/4 wire 10…500 V AC
  • 1 A/ 5 A current inputs
  • Serial interface to RTU500 series (RS-485)

Flexibility of communication is a precondition for modern RTU systems. The RTU500 series guarantees an error-free and comprehensive communication to a variety of devices.

Analog modems are used for serial communication. The RTU500 series modules offer modems with speed rates up to 9.600 Baud for distances up to 20 km. The modems operate in wide or voice band range to meet customer requirements. Moreover, the modems are available for CCITT V.23 standard.

560FOC40 Optical coupler (850 nm)

  • Direct connection to serial peripheral bus (SPB)
  • For potential isolation of SPB
  • Emission wave length: 850 nm
  • Input optical power: Min. - 24.0 dBm - Max. -10.0 dBm
  • Transmission rate: 1 Mbit max.
  • Connects in star or multipoint T-configuration
  • Auxiliary voltage: 24 V DC

560FSM10: Modem V.23

Voice frequency telegraphy device (VFT) according CCITT V.23 standard/ 1200 baud.

  • Can be connected to 23WT23
  • DIN rail mounted
  • Auxiliary voltage: 24...60 V DC

 

560FSM11: Modem 9600 baud

FSK device with 9600 baud transmission speed

  • Can be connected to 23WT24
  • DIN rail mounted
  • Isolation test voltage 3 kV
  • Communication over pilot cable
  • Auxiliary voltage: 24...60 V DC

500LTD01 Line transformer

Isolated line transformer for galvanic isolation of transmission line

  • Frequency range: 0,3 kHz to 3.4 kHz
  • Ratio 1:1
  • Isolation test voltage 10 kV
  • Optimized for line impedances of 600 Ω
  • Insulation resistance: 10000 MΩ at 500 V

560LTD02: Line transformer 7.5 kV, 2-50 kHz

Isolated line transformer for galvanic isolation of transmission line

  • Operates at a frequency range from 2 kHz to 50 kHz (23WT24 and 560FSM11)
  • Isolation test voltage 7.5 kV
  • Optimized for line impedances of 150 Ω
  • Ratio 1:1
  • Insulation resistance: 10000 MΩ at 500 V between windings and the case

Flexibility of communication is a precondition for modern RTU systems. The RTU500 series guarantees an error-free and comprehensive communication to a variety of devices.

DSL modems: 4 port Ethernet switches distribute Ethernet with support of redundant topologies. Copper as well as fiber optical media are supported. Available copper lines can be re-used for TCP/IP communication, allowing for an independent network for private communication. Additionally, tunneling of serial data via RS 232 interface allows for an easy migration from serial to Ethernet communication. 

560NMD01: DIN rail integrated managed switch

  • Integrated managed layer-2-switch
  • 4x 10/100 BaseT port (RJ45, electrical, auto negotiating)
  • 1x SDSL-port for copper wire (pilot cable)
  • Provides (Rapid) Spanning Tree Protocol (RSTP) support
  • Provides redundant topologies by the (Rapid) Spanning Tree Protocol (RSTP)

560NMD02: DIN rail integrated managed switch

  • Integrated managed layer-2-switch
  • 4x 10/100 BaseT port (RJ45, electrical, auto negotiating)
  • 2x SDSL-port for copper wire
  • Provides (Rapid) Spanning Tree Protocol (RSTP) support
  • Communication with serial protocols
  • Provides redundant topologies by the (Rapid) Spanning Tree Protocol (RSTP)

560NMD11: DIN rail integrated managed switch

  • Integrated managed layer-2-switch
  • 4x 10/100 BaseT port (RJ45, electrical, auto negotiating)
  • 1x SFP slot, without optical transmitter/receiver
  • Additional SFP modules are required (see 560NFOxx)
  • 1x SDSL-port for copper wire
  • Provides (Rapid) Spanning Tree Protocol (RSTP) support
  • 2x RS-232 ports for serial communication protocols

500MDD01 GSM/GPRS/Edge DIN rail modem

  • Wireless Ethernet communication via serial interface (RS232C standard) with point-to-point protocol (PPP) Plastic DIN rail housing
  • Integrated Quad-Band GSM/GPRS/Edge modem
Contact us